Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
2.
J Clin Med ; 12(22)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38002639

RESUMO

There are known pathophysiologic and clinical differences according to sex in patients with aortic stenosis (AS). To evaluate if these differences persist after valve replacement, we conducted an observational study including 451 patients with symptomatic AS who survived aortic valve intervention (AVI) in two centers. Clinical data and mortality were evaluated at a mean follow-up of 5 years. 56% of patients were women. At baseline, women were older (80.6 vs. 78 years, p = 0.013), presented higher mean gradient (48 vs. 45 mmHg, p = 0.023), lower aortic valve area (0.70 vs. 0.74 cm2, p = 0.002) and higher systolic pulmonary artery pressure (36 vs. 33 mmHg, p = 0.016). They underwent percutaneous aortic valve replacement more frequently than men (47 vs. 35.9%, p = 0.017). At 5 years follow-up, women required more admissions due to heart failure (23 vs. 9%, p = 0.046) but they did not present higher cardiovascular nor overall mortality (27.7% vs. 29.8%, p = 0.741; 11.1 vs. 10.1%, p = 0.619, respectively). Female sex was an independent predictor of heart failure hospitalization at follow-up (HR 95% 1.16-4.22, p = 0.016). Women undergo AVI at a more advanced stage than men, resulting in a higher frequency of readmissions due to heart failure during the follow-up period, but not in higher mortality.

3.
Heart ; 109(21): 1631-1638, 2023 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-37286345

RESUMO

OBJECTIVE: The recurrence of syncope after valve intervention in severe aortic stenosis (SAS) and its impact on outcome are unknown. We hypothesised that syncope on exertion will disappear after intervention, whereas syncope at rest might recur. Our aim has been to describe the recurrence of syncope in patients with SAS undergoing valve replacement and its impact on mortality. METHODS: Double-centre observational registry of 320 consecutive patients with symptomatic SAS without other valve disease and/or coronary artery disease who underwent valve intervention and were discharged alive. All-cause mortality and cardiovascular mortality were considered events. RESULTS: 53 patients (median age 81 years, 28 men) had syncope (29 on exertion, 21 at rest, 3 unknown). Clinical and echocardiographic variables were similar in patients with and without syncope (median vmax 4.44 m/s, mean gradient 47 mm Hg, valve area 0.7 cm2, left ventricular ejection fraction 62%). After a median follow-up of 69 months (IQR: 55-88), syncope on exertion did not recur in any patient. In contrast, 8 of the 21 patients with syncope at rest had postintervention syncope at rest (38%; p<0.001): 3 needed a pacemaker, 3 were neuromediated or hypotensive and 2 arrhythmic. Only recurrence of syncope was associated with cardiovascular mortality (HR 5.74; 95% CI 2.17 to 15.17; p<0.001). CONCLUSIONS: Syncope on exertion in patients with SAS did not recur after aortic valve intervention. Syncope at rest recurs in a high proportion of patients and identifies a population with increased mortality. According to our results, syncope at rest should be thoroughly evaluated before proceeding to aortic valve intervention.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Volume Sistólico , Síncope/diagnóstico , Síncope/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
4.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36898524

RESUMO

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Desenho de Prótese
5.
J Cardiovasc Dev Dis ; 11(1)2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38248884

RESUMO

Background: Quantitative flow ratio (QFR) virtual angioplasty with pre-PCI residual QFR showed better results compared with an angiographic approach to assess post-PCI functional results. However, correlation with pre-PCI residual QFR and post-PCI fractional flow reserve (FFR) is lacking. Methods: A multicenter prospective study including consecutive patients with angiographically 50-90% coronary lesions and positive QFR results. All patients were evaluated with QFR, hyperemic and non-hyperemic pressure ratios (NHPR) before and after the index PCI. Pre-PCI residual QFR (virtual angioplasty) was calculated and compared with post-PCI fractional flow reserve (FFR), QFR and NHPR. Results: A total of 84 patients with 92 treated coronary lesions were included, with a mean age of 65.5 ± 10.9 years and 59% of single vessel lesions being the left anterior descending artery in 69%. The mean vessel diameter was 2.82 ± 0.41 mm. Procedural success was achieved in all cases, with a mean number of implanted stents of 1.17 ± 0.46. The baseline QFR value was 0.69 ± 0.12 and baseline FFR and NHPR were 0.73 ± 0.08 and 0.82 ± 0.11, respectively. Mean post-PCI FFR increased to 0.87 ± 0.05 whereas residual QFR had been estimated as 0.95 ± 0.05, showing poor correlation with post-PCI FFR (0.163; 95% CI:0.078-0.386) and low diagnostic accuracy (30.9%, 95% CI:20-43%). Conclusions: In this analysis, the results of QFR-based virtual angioplasty did not seem to accurately correlate with post-PCI FFR.

6.
Int J Mol Sci ; 23(23)2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36499671

RESUMO

Recent works have demonstrated a significant reduction in cholesterol levels and increased oxidative stress in patients with coronavirus disease 2019 (COVID-19). The cause of this alteration is not well known. This study aimed to comprehensively evaluate their possible association during the evolution of COVID-19. This is an observational prospective study. The primary endpoint was to analyze the association between lipid peroxidation, lipid, and inflammatory profiles in COVID-19 patients. A multivariate regression analysis was employed. The secondary endpoint included the long-term follow-up of lipid profiles. COVID-19 patients presented significantly lower values in their lipid profile (total, low, and high-density lipoprotein cholesterol) with greater oxidative stress and inflammatory response compared to the healthy controls. Lipid peroxidation was the unique oxidative parameter with a significant association with the total cholesterol (OR: 0.982; 95% CI: 0.969-0.996; p = 0.012), IL1-RA (OR: 0.999; 95% CI: 0.998-0.999; p = 0.021) IL-6 (OR: 1.062; 95% CI: 1.017-1.110; p = 0.007), IL-7 (OR: 0.653; 95% CI: 0.433-0.986; p = 0.042) and IL-17 (OR: 1.098; 95% CI: 1.010-1.193; p = 0.028). Lipid abnormalities recovered after the initial insult during long-term follow-up (IQR 514 days); however, those with high LPO levels at hospital admission had, during long-term follow-up, an atherogenic lipid profile. Our study suggests that oxidative stress in COVID-19 is associated with derangements of the lipid profile and inflammation. Survivors experienced a recovery in their lipid profiles during long-term follow-up, but those with stronger oxidative responses had an atherogenic lipid profile.


Assuntos
Aterosclerose , COVID-19 , Dislipidemias , Humanos , Seguimentos , Estudos Prospectivos , Inflamação , Estresse Oxidativo , HDL-Colesterol
7.
Artigo em Inglês | MEDLINE | ID: mdl-35409644

RESUMO

Background (1): Headache is a prevalent symptom experienced during ongoing SARS-CoV-2 infection, but also weeks after recovery. Whether cardio-pulmonary dysfunction contributes causally to headache persistence is unknown. Methods (2): We conducted a case-control analysis nested in a prospective cohort study. Individuals were recruited from August 2020 to December 2020. Patients were grouped according to the presence or absence of long-COVID headache for three months after COVID-19 resolution. We compared demographic data, clinical variables, cardio-pulmonary laboratory biomarkers, quality of life, and cardio-pulmonary function between groups. Results (3): A cohort of 70 COVID-19 patients was evaluated. Patients with headaches (n = 10; 14.3%) were more frequently female (100% vs. 58.4%; p = 0.011) and younger (46.9 ± 8.45 vs. 56.13 ± 12 years; p = 0.023). No between-group differences in laboratory analysis, resting echocardiography, cardio-pulmonary exercise test, or pulmonary function tests were observed. Conclusion (4): In this exploratory study, no significant differences in cardio-pulmonary dysfunction were observed between patients with and without long-COVID headache during mid-term follow-up.


Assuntos
COVID-19 , COVID-19/complicações , Feminino , Cefaleia/etiologia , Humanos , Estudos Prospectivos , Qualidade de Vida , SARS-CoV-2 , Síndrome Pós-COVID-19 Aguda
8.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1001-1010, 2022 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35272968

RESUMO

INTRODUCTION AND OBJECTIVES: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. METHODS: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs. RESULTS: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011). CONCLUSIONS: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Neprilisina , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/cirurgia , Neprilisina/antagonistas & inibidores , Receptores de Angiotensina , Resultado do Tratamento
9.
JACC Cardiovasc Interv ; 15(2): 135-146, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057983

RESUMO

OBJECTIVES: The aims of this study were to determine the rate of noncentered coronary ostia and their risk for coronary overlap (CO) and to develop an improved orientation strategy for transcatheter aortic valve replacement (TAVR) devices taking into account anatomical cues to identify patients at risk for CO regardless of commissural alignment and compute an alternative, CO-free TAVR rotation angle for those patients. BACKGROUND: Commissural alignment during TAVR reduces CO risk. However, eccentricity of coronary ostia from the center of the sinus of Valsalva may result in CO even after perfect alignment of TAVR commissures. METHODS: Baseline computed tomography from TAVR candidates helped identify distance from commissures to the right coronary artery (RCA) and the left coronary artery (LCA). Then, for each case, a virtual valve was simulated with ideal commissural or coronary alignment, and the degree of CO was determined. On the basis of the potential BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) efficacy, 3 groups were defined: no risk for CO (>35° from neocommissure to coronary ostia), moderate risk (20°-35°), and severe risk (≤20°). RESULTS: Computed tomographic studies from 107 patients were included. After excluding 7 patients (poor quality or bicuspid valve), 100 patients were analyzed. The RCA showed greater eccentricity compared with the LCA (18.5° [IQR: 3.3°-12.8°] vs 6.5° [IQR: 3.3°-12.8°]; P < 0.001). The mean intercoronary angle was 140.0° ± 18.7° (95% CI: 136.3°-143.7°). Thirty-two patients had moderate to severe risk for CO (≤35°) despite ideal commissural alignment. Greater coronary eccentricity (cutoff for RCA, 24.5°; cutoff for LCA, 19°) and intercoronary angle >147.5° or <103° were associated with greater risk for moderate to severe CO despite commissural alignment (area under the curve: 0.97; 95% CI: 0.91-0.99). If optimal coronary alignment was simulated, this prevented severe CO in all cases and reduced moderate CO from 27% to 5% (P < 0.001). CONCLUSIONS: One third of patients would have CO during TAVR-in-TAVR despite commissural alignment; a 6-fold decrease in this risk was achieved with optimized coronary alignment. Coronary eccentricity and intercoronary angle were the main predictors.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
10.
Rev Esp Cardiol (Engl Ed) ; 75(3): 203-212, 2022 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33781722

RESUMO

INTRODUCTION AND OBJECTIVES: Final position of the neo-commissures is uncontrolled during transcatheter aortic valve implantation (TAVI), potentially hindering coronary access and future procedures. We aimed to develop a standard method to achieve commissural alignment with the ACURATE neo valve. METHODS: The relationship between native and TAVI neo-commissures was analyzed in 11 severe aortic stenosis patients undergoing TAVI. Based on computed tomography analysis, an in silico model was developed to predict final TAVI commissural posts position. A modified implantation technique, accurate commissural alignment (ACA) and a dedicated delivery system were developed. TAVI implants were tested in 3-dimensional (3D) printed models and in vivo. Commissural misalignment and coronary overlap (CO) were analyzed. RESULTS: The in silico model accurately predicted final position of commissural posts irrespective of the implantation technique performed (correlation coefficient, 0.994; 95%CI, 0.989-0.998; P<.001). TAVI implant with patient-specific rotation was simulated in 3D printed models and in 9 patients. ACA-oriented TAVI implants presented adequate commissural alignment in vivo (mean commissural misalignment of 7.7 ±3.9°). None of the ACA oriented implants showed CO, whereas in silico conventional implants predicted CO in 6 of the 9 cases. CONCLUSIONS: Accurate commissural alignment of the ACURATE neo device is feasible by inserting the delivery system with a patient-specific rotation based on computed tomography analysis. This is a simple and reproducible method for commissural alignment that can be potentially used for all kinds of TAVI devices.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
11.
Heart ; 107(24): 1987-1994, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34509995

RESUMO

OBJECTIVE: To evaluate the prognostic impact of urgent cardiac surgery on the prognosis of left-sided infective endocarditis (LSIE) and its relationship to the basal risk of the patient and to the surgical indication. METHODS: 605 patients with LSIE and formal surgical indication were consecutively recruited between 2000 and 2020 among three tertiary centres: 405 underwent surgery during the active phase of the disease and 200 did not despite having indication. The prognostic impact of urgent surgery was evaluated by multivariable analysis and propensity score analysis. We studied the benefit of surgery according to baseline mortality risk defined by the ENDOVAL score and according to surgical indication. RESULTS: Surgery is an independent predictor of survival in LSIE with surgical indication both by multivariable analysis (OR 0.260, 95% CI 0.162 to 0.416) and propensity score (mortality 40% vs 66%, p<0.001). Its greatest prognostic benefit is seen in patients at highest risk (predicted mortality 80%-100%: OR 0.08, 95% CI 0.021 to 0.299). The benefit of surgery is especially remarkable for uncontrolled infection indication (OR 0.385, 95% CI 0.194 to 0.765), even in combination with heart failure (OR 0.220, 95% CI 0.077 to 0.632). CONCLUSIONS: Surgery during active LSIE seems to significantly reduce in-hospital mortality. The higher the risk, the higher the improvement in outcome.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Endocardite Bacteriana/complicações , Cardiopatias/cirurgia , Pontuação de Propensão , Medição de Risco/métodos , Idoso , Procedimentos Cirúrgicos Cardíacos/mortalidade , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/mortalidade , Feminino , Seguimentos , Cardiopatias/complicações , Cardiopatias/mortalidade , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências
12.
Nutr Metab Cardiovasc Dis ; 31(9): 2619-2627, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34353699

RESUMO

BACKGROUND AND AIMS: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the sole causative agent of coronavirus infectious disease-19 (COVID-19). METHODS AND RESULTS: We performed a retrospective single-center study of consecutively admitted patients between March 1st and May 15th, 2020, with a definitive diagnosis of SARS-CoV-2 infection. The primary end-point was to evaluate the association of lipid markers with 30-days all-cause mortality in COVID-19. A total of 654 patients were enrolled, with an estimated 30-day mortality of 22.8% (149 patients). Non-survivors had lower total cholesterol (TC) and low-density lipoprotein cholesterol (LDL-c) levels during the entire course of the disease. Both showed a significant inverse correlation with inflammatory markers and a positive correlation with lymphocyte count. In a multivariate analysis, LDL-c ≤ 69 mg/dl (hazard ratio [HR] 1.94; 95% confidence interval [CI] 1.14-3.31), C-reactive protein >88 mg/dl (HR 2.44; 95% CI, 1.41-4.23) and lymphopenia <1000 (HR 2.68; 95% CI, 1.91-3.78) at admission were independently associated with 30-day mortality. This association was maintained 7 days after admission. Survivors presented with complete normalization of their lipid profiles on short-term follow-up. CONCLUSION: Hypolipidemia in SARS-CoV-2 infection may be secondary to an immune-inflammatory response, with complete recovery in survivors. Low LDL-c serum levels are independently associated with higher 30-day mortality in COVID-19 patients.


Assuntos
COVID-19/sangue , LDL-Colesterol/sangue , Dislipidemias/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , COVID-19/diagnóstico , COVID-19/mortalidade , COVID-19/terapia , Regulação para Baixo , Dislipidemias/diagnóstico , Dislipidemias/mortalidade , Dislipidemias/terapia , Feminino , Humanos , Mediadores da Inflamação/sangue , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Espanha , Fatores de Tempo
13.
J Clin Med ; 10(12)2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34208271

RESUMO

INTRODUCTION: Coronavirus disease 2019 (COVID-19) is a systemic disease characterized by a disproportionate inflammatory response in the acute phase. This study sought to identify clinical sequelae and their potential mechanism. METHODS: We conducted a prospective single-center study (NCT04689490) of previously hospitalized COVID-19 patients with and without dyspnea during mid-term follow-up. An outpatient group was also evaluated. They underwent serial testing with a cardiopulmonary exercise test (CPET), transthoracic echocardiogram, pulmonary lung test, six-minute walking test, serum biomarker analysis, and quality of life questionaries. RESULTS: Patients with dyspnea (n = 41, 58.6%), compared with asymptomatic patients (n = 29, 41.4%), had a higher proportion of females (73.2 vs. 51.7%; p = 0.065) with comparable age and prevalence of cardiovascular risk factors. There were no significant differences in the transthoracic echocardiogram and pulmonary function test. Patients who complained of persistent dyspnea had a significant decline in predicted peak VO2 consumption (77.8 (64-92.5) vs. 99 (88-105); p < 0.00; p < 0.001), total distance in the six-minute walking test (535 (467-600) vs. 611 (550-650) meters; p = 0.001), and quality of life (KCCQ-23 60.1 ± 18.6 vs. 82.8 ± 11.3; p < 0.001). Additionally, abnormalities in CPET were suggestive of an impaired ventilatory efficiency (VE/VCO2 slope 32 (28.1-37.4) vs. 29.4 (26.9-31.4); p = 0.022) and high PETCO2 (34.5 (32-39) vs. 38 (36-40); p = 0.025). INTERPRETATION: In this study, >50% of COVID-19 survivors present a symptomatic functional impairment irrespective of age or prior hospitalization. Our findings suggest a potential ventilation/perfusion mismatch or hyperventilation syndrome.

14.
Rev. esp. cardiol. (Ed. impr.) ; 74(5): 421-426, may. 2021. tab, graf
Artigo em Inglês, Espanhol | IBECS | ID: ibc-232554

RESUMO

Introducción y objetivos Determinar si la prescripción de inhibidores del sistema renina-angiotensina (iSRA) se asocia a mejores resultados tras implante percutáneo de válvula aórtica (TAVI) o recambio valvular aórtico quirúrgico (RVAQ). Métodos Se seleccionaron de PubMed, Web of Science, y Google Scholar hasta agosto de 2019 estudios comparativos de iSRA vs no-iSRA en pacientes sometidos a TAVI/RVAQ. Se extrajeron las hazard ratios (HR) con sus intervalos de confianza para mortalidad de cada estudio y estimadores específicos en el modelo de efectos aleatorios. Resultados Se incluyeron 6 estudios con un total de 21.390 pacientes (TAVI: 17.846, RVAQ: 3.544). Los 6 fueron estudios comparativos (3 análisis de propensión y 3 de cohortes) comparando iSRA vs no-iSRA. Se demostró que la prescripción de iSRA se asocia con una mortalidad significativamente menor en pacientes sometidos a intervención valvular aórtica (HR=0,64; IC95%, 0,47-0,88; p <0,001). Sin embargo, el análisis por subgrupos sugirió diferencias en función de la terapia seleccionada, con menor mortalidad en los sometidos a TAVI tratados con iSRA (HR=0,67; IC95%, 0,49-0,93) pero no en los tratados con RVAQ (HR=0,61; IC95%, 0,29-1,30). No se identificó asimetría en el análisis funnel plot, sugiriendo bajo riesgo de sesgo de publicación. El análisis de sensibilidad eliminando sucesivamente diferentes estudios no alteró de forma substancial el resultado. Conclusiones Estos resultados sugieren reducción de la mortalidad con la prescripción de iSRA en pacientes con estenosis aórtica sometidos a recambio valvular aórtico, en particular tras TAVI. Futuros estudios aleatorizados deberán confirmar o refutar este relevante hallazgo. (AU)


Introduction and objectives To determine whether renin-angiotensin system inhibitor (RASi) prescription is associated with better outcomes after transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). Methods All comparative studies of RASi vs no RASi prescription in patients undergoing TAVI/SAVR were gathered from PubMed, Web of Science, and Google Scholar through August, 2019. We extracted hazard ratios (HRs) with their confidence intervals (CIs) for mortality from each study and combined study-specific estimates using inverse variance-weighted averages of logarithmic HRs in the random effects model. Results We identified 6 eligible studies with a total of 21 390 patients (TAVI: 17 846; SAVR: 3544) and included them in the present meta-analysis. The 6 studies were observational comparative studies (including 3 propensity score matched and 3 cohort studies) of RASi vs no RASi prescription. The analysis demonstrated that RASi prescription was associated with significantly lower mortality in the whole group of patients undergoing aortic valve intervention (HR, 0.64; 95%CI, 0.47-0.88; P <.001). However, subgroup analysis suggested differences according to the selected therapy, with TAVI showing better mortality rates in the RASi group (HR, 0.67; 95%CI, 0.49-0.93) but not in the SAVR group (HR, 0.61; 95%CI, 0.29-1.30). No funnel plot asymmetry was identified, suggesting minimum publication bias. Sensitivity analyses sequentially eliminating dissimilar studies did not substantially alter the primary result favoring RASI prescription. Conclusions These findings suggest a mortality benefit of RASi in patients with AS treated with aortic valve replacement that might be particularly relevant following TAVI. Future randomized studies are warranted to confirm this relevant finding. (AU)


Assuntos
Humanos , Inibidores da Angiogênese , Substituição da Valva Aórtica Transcateter , Valva Aórtica
15.
Rev Esp Cardiol (Engl Ed) ; 74(5): 421-426, 2021 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32402685

RESUMO

INTRODUCTION AND OBJECTIVES: To determine whether renin-angiotensin system inhibitor (RASi) prescription is associated with better outcomes after transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). METHODS: All comparative studies of RASi vs no RASi prescription in patients undergoing TAVI/SAVR were gathered from PubMed, Web of Science, and Google Scholar through August, 2019. We extracted hazard ratios (HRs) with their confidence intervals (CIs) for mortality from each study and combined study-specific estimates using inverse variance-weighted averages of logarithmic HRs in the random effects model. RESULTS: We identified 6 eligible studies with a total of 21 390 patients (TAVI: 17 846; SAVR: 3544) and included them in the present meta-analysis. The 6 studies were observational comparative studies (including 3 propensity score matched and 3 cohort studies) of RASi vs no RASi prescription. The analysis demonstrated that RASi prescription was associated with significantly lower mortality in the whole group of patients undergoing aortic valve intervention (HR, 0.64; 95%CI, 0.47-0.88; P <.001). However, subgroup analysis suggested differences according to the selected therapy, with TAVI showing better mortality rates in the RASi group (HR, 0.67; 95%CI, 0.49-0.93) but not in the SAVR group (HR, 0.61; 95%CI, 0.29-1.30). No funnel plot asymmetry was identified, suggesting minimum publication bias. Sensitivity analyses sequentially eliminating dissimilar studies did not substantially alter the primary result favoring RASI prescription. CONCLUSIONS: These findings suggest a mortality benefit of RASi in patients with AS treated with aortic valve replacement that might be particularly relevant following TAVI. Future randomized studies are warranted to confirm this relevant finding.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema Renina-Angiotensina , Fatores de Risco , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 97(5): 807-814, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32196932

RESUMO

INTRODUCTION: Despite of the wide evidence of use fractional flow reserve (FFR), isolated angiography evaluation is still the main tool to indicate percutaneous coronary intervention. Quantitative flow ratio (QFR) is a new functional index to assess functional significance. Recently, few studies have showed the capacity of QFR to predict significance stenosis. The aim of this research has been to describe the evidence of QFR in this clinical setting, to analyze the global diagnosis accuracy of QFR versus FFR and to compare the difference in feasibility between retrospective and prospective analysis. METHODS AND RESULTS: Systematic review of literature was performed. Eligible studies for the meta-analysis were considered those directly evaluating de QFR versus FFR. Pooled values of diagnosis test and summary receiver operator curve were calculated. Main causes of not-perform QFR analysis according to study design were also evaluated. Sixteen studies were included. Good correlation and agreement were showed. Global sensibility, specificity, PPV, and NPV were 0.84, 0.89, 0.80, and 0.92, respectively. Then, 18% of evaluated vessels could not be analyzed. Significant differences were found in the percentage of discarded vessels and the cause of nonperformed analysis between retrospective or prospective analysis. CONCLUSIONS: Excellent correlation and agreement between QFR and FFR was demonstrated. QFR assessment could be improved by its prospective analysis with a dedicated protocol.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
17.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1032-1041, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33158760

RESUMO

INTRODUCTION AND OBJECTIVES: Aortic self-expandable (SE) transcatheter aortic valve implantation (TAVI) devices are particularly useful for patients with aortic stenosis and small/tortuous vessels, small aortic annuli, or low coronary ostia. However, it is unclear whether the growing range of SE devices shows comparable hemodynamic and clinical outcomes. We aimed to determine the differential hemodynamic (residual valve area and regurgitation) and clinical outcomes of these devices in comparable scenarios. METHODS: All patients were enrolled from 4 institutions and were managed with 4 different SE TAVI devices. Baseline and follow-up clinical data were collected and echocardiographic tests blindly and centrally analyzed. Patients were compared according to valve type and a 1:1 matched comparison was performed according to degree of calcification, aortic annulus dimensions, left ventricular ejection fraction, and body surface area. RESULTS: In total, 514 patients were included (Evolut R/PRO, 217; ACURATE neo, 107; ALLEGRA, 102; Portico, 88). Surgical risk scores were comparable in the unmatched population. No differences were observed in the post-TAVI regurgitation rate and in in-hospital mortality (2.7%). The rate of pacemaker implantation at discharge was significantly different among devices (P=.049), with Portico showing the highest rate (23%) and ACURATE neo the lowest (9.5%); Evolut R/PRO and ALLEGRA had rates of 15.9% and 21.2%, respectively. The adjusted comparison showed worse residual TAVI gradients and aortic valve area with ACURATE neo vs ALLEGRA (P=.001) but the latter had higher risk of valve embolization and a tendency for more cerebrovascular events. CONCLUSIONS: A matched comparison of 4 SE TAVI devices showed no differences regarding residual aortic regurgitation and in-hospital mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
18.
JACC Cardiovasc Interv ; 13(17): 1983-1996, 2020 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-32912458

RESUMO

OBJECTIVES: This study aimed to evaluate the safety and mid-term efficacy of transcatheter aortic valve replacement (TAVR) in the setting of aortic valve (AV) infective endocarditis (IE) with residual lesion despite successful antibiotic treatment. BACKGROUND: Patients with AV-IE presenting residual lesion despite successful antibiotic treatment are often rejected for cardiac surgery due to high-risk. The use of TAVR following IE is not recommended. METHODS: This was a multicenter retrospective study across 10 centers, gathering baseline, in-hospital, and 1-year follow-up characteristics of patients with healed AV-IE treated with TAVR. Matched comparison according to sex, EuroSCORE, chronic kidney disease, left ventricular function, prosthesis type, and valve-in-valve procedure was performed with a cohort of patients free of prior IE treated with TAVR (46 pairs). RESULTS: Among 2,920 patients treated with TAVR, 54 (1.8%) presented with prior AV-IE with residual valvular lesion and healed infection. They had a higher rate of multivalvular disease and greater surgical risk scores. A previous valvular prosthesis was more frequent than a native valve (50% vs. 7.5%; p < 0.001). The in-hospital and 1-year mortality rates were 5.6% and 11.1%, respectively, comparable to the control cohort. After matching, the 1-year III to IV aortic regurgitation rate was 27.9% (vs. 10%; p = 0.08) and was independently associated with higher mortality. There was only 1 case of IE relapse (1.8%); however, 18% of patients were complicated with sepsis, and 43% were readmitted due to heart failure. CONCLUSIONS: TAVR is a safe therapeutic alternative for residual valvular lesion after successfully healed AV-IE. At 1-year follow-up, the risk of IE relapse was low and mortality rate did not differ from TAVR patients free of prior IE, but one-fourth presented with significant aortic regurgitation and >50% required re-admission.


Assuntos
Valva Aórtica/cirurgia , Endocardite Bacteriana/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/microbiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/mortalidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/microbiologia , Doenças das Valvas Cardíacas/mortalidade , Próteses Valvulares Cardíacas/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
19.
J Am Coll Cardiol ; 76(3): 268-276, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32470515

RESUMO

BACKGROUND: Coronavirus disease-2019 (COVID-19) is caused by severe acute respiratory-syndrome coronavirus-2 that interfaces with the renin-angiotensin-aldosterone system (RAAS) through angiotensin-converting enzyme 2. This interaction has been proposed as a potential risk factor in patients treated with RAAS inhibitors. OBJECTIVES: This study analyzed whether RAAS inhibitors modify the risk for COVID-19. METHODS: The RASTAVI (Renin-Angiotensin System Blockade Benefits in Clinical Evolution and Ventricular Remodeling After Transcatheter Aortic Valve Implantation) trial is an ongoing randomized clinical trial randomly allocating subjects to ramipril or control groups after successful transcatheter aortic valve replacement at 14 centers in Spain. A non-pre-specified interim analysis was performed to evaluate ramipril's impact on COVID-19 risk in this vulnerable population. RESULTS: As of April 1, 2020, 102 patients (50 in the ramipril group and 52 in the control group) were included in the trial. Mean age was 82.3 ± 6.1 years, 56.9% of the participants were male. Median time of ramipril treatment was 6 months (interquartile range: 2.9 to 11.4 months). Eleven patients (10.8%) have been diagnosed with COVID-19 (6 in control group and 5 receiving ramipril; hazard ratio: 1.150; 95% confidence interval: 0.351 to 3.768). The risk of COVID-19 was increased in older patients (p = 0.019) and those with atrial fibrillation (p = 0.066), lower hematocrit (p = 0.084), and more comorbidities according to Society of Thoracic Surgeons score (p = 0.065). Admission and oxygen supply was required in 4.9% of patients (2 in the ramipril group and 3 in the control group), and 4 of them died (2 in each randomized group). A higher body mass index was the only factor increasing the mortality rate (p = 0.039). CONCLUSIONS: In a high-risk population of older patients with cardiovascular disease, randomization to ramipril had no impact on the incidence or severity of COVID-19. This analysis supports the maintenance of RAAS inhibitor treatment during the COVID-19 crisis. (Renin-Angiotensin System Blockade Benefits in Clinical Evolution and Ventricular Remodeling After Transcatheter Aortic Valve Implantation [RASTAVI]; NCT03201185).


Assuntos
Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Infecções por Coronavirus/mortalidade , Pneumonia Viral/mortalidade , Ramipril/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus , COVID-19 , Infecções por Coronavirus/induzido quimicamente , Feminino , Humanos , Masculino , Pandemias , Pneumonia Viral/induzido quimicamente , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , SARS-CoV-2 , Espanha/epidemiologia
20.
Cardiol J ; 27(5): 524-532, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32329042

RESUMO

BACKGROUND: Atrial septal defect (ASD) is one of the most common congenital heart diseases. Percutaneous closure is the preferred treatment, but certain complications remain a concern. The most common devices are AMPLATZER™ (ASO) (St. Jude Medical, St. Paul, MN, USA) and Figulla Flex® septal occluders (FSO) (Occlutech GmbH, Jena, Germany). The present study aimed to assess main differences in outcomes. METHODS: A systematic search in Pubmed and Google scholarship was performed by two independent reviewers for any study comparing ASO and FSO. Searched terms were "Figulla", "Amplatzer", and "atrial septal defect". A random-effects model was used. RESULTS: A total of 11 studies including 1770 patients (897 ASO; 873 FSO) were gathered. Baseline clinical and echocardiographic characteristics were comparable although septal aneurysm was more often reported in patients treated with ASO (32% vs. 25%; p = 0.061). Success rate (94% vs. 95%; OR: 0.81; 95% CI: 0.38-1.71; p = 0.58) and peri-procedural complications were comparable. Procedures were shorter, requiring less fluoroscopy time with an FSO device (OR: 0.59; 95% CI: 0.20-0.97; p = 0.003). Although the global rate of complications in long-term was similar, the ASO device was associated with a higher rate of supraventricular arrhythmias (14.7% vs. 7.8%, p = 0.009). CONCLUSIONS: Percutaneous closure of ASD is a safe and effective, irrespective of the type of device. No differences exist regarding procedural success between the ASO and FSO devices but the last was associated to shorter procedure time, less radiation, and lower rate of supraventricular arrhythmias in follow-up. Late cardiac perforation did not occur and death in the follow-up was exceptional.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Ecocardiografia , Alemanha , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...